Welcome To our shop !

HVACDIRECT Refrigeration & HVAC Split System Install Kit (Pump, Leak Detector, Tube Cutter & Manifold Set)

$149.00 $366.82

HVACDIRECT Refrigeration & HVAC Split System Install Kit (Pump, Leak Detector, Tube Cutter & Manifold Set)KIT3This HVACDIRECT KIT3, HVACDIRECT Refrigeration & HVAC Split System Install Kit (Pump, Leak Detector, Tube Cutter & Manifold Set) is a high quality

Qty:

Payment:

Payment Option Image

HVACDIRECT Refrigeration & HVAC Split System Install Kit (Pump, Leak Detector, Tube Cutter & Manifold Set)

KIT3

This HVACDIRECT KIT3, HVACDIRECT Refrigeration & HVAC Split System Install Kit (Pump, Leak Detector, Tube Cutter & Manifold Set) is a high quality tool kit that is ideal for general refrigeration and split system service. Included in this kit are some of HVAC Direct’s best selling products.

Kit contains:

#1.HVACDIRECT45 L/min, 2-Stage Refrigeration Vacuum Pump

VP215N

This HVACDIRECT VP215N, Refrigeration Vacuum Pumpis a quality 2 stage, oil rotary vane pump with a 45 L/min flow rate and a 15 micron ultimate vacuum.

This pump is ideal for general refrigeration service, and is packed with the features below.

Applications:

  • General refrigeration

  • Bottle shops and convenient stores

  • Restaurants, cafes and catering facilities

  • Household or residential jobs including split systems

  • Commercial work

Features/Benefits:

  • Comes with a free starter bottle of oil

  • Great value for money

  • Anti-oil demister to prevent oil spillage

  • Fitted with 1/4″ SAE connection

  • 45 L/min flow rate

  • 15 micron ultimate vacuum

  • 230ml oil capacity

  • Dimensions (mm): 240x93x200

  • Weight (kg): 4.3kg

Refrigerants:

R12, R134a, R401C, R406A, R500,R22, R401A, R401B, R402B, R407C, R407D, R408A, R409A, R411A, R411B, R412A, R502, R509,R402A, R404A, R407A, R407B, R410A & R507

#2. HVACDIRECT 2-Valve Refrigeration Manifold Set – R32 & R410a Compliant

HMG2R32II

This HVACDIRECT HMG2R32II, Refrigeration Manifold & Hose Set is a high quality manifold set option that provides an ease of use as well as accurate results.

Features:

  • Temperature in Celsius for R32, R410a

  • Class 1.6 gauges – Ideal when purchasing a quality manifold

  • Large 70 mm diameter easy-to-read dual gauges

  • Manifold incorporates built-in sight glass

  • High pressure or low pressure is selectable

  • Piston valves for more positive seal and less wear

  • Extra large easy to read colour-coded dials

  • Full rubber gauge housing for added protection

  • Durable metal casing

  • Aluminium alloy testing manifold body

  • High impact pop-in lexan lens

  • A heavy duty hook for hanging the gauges

  • No-flutter gauge design

  • 1/4″ SAE brass connections

  • 5/16″ SAE adaptors to allow switching between different systems

Specifications:

  • 3 x 0.9 m 1/4″ SAE charging hoses: Red, yellow & blue

  • Working pressure:800 psi

  • Burst pressure:4000 psi

  • Designed to meet 1/4″ SAE refrigerant permutation requirement

#3.HVACDIRECT Refrigerant Leak Detector (Halogen)

HLD100

This HVACDIRECT HLD100, Refrigerant Leak Detector is a device that features high performance, powerful function, extreme sensitivity and is very easy to operate.

Features:

  • Detects all kinds of halogenated refrigerants

  • Single colour LED display with 6-level leak alarm

  • Tricolour display of battery voltage

  • Reset time sensitivity adjustment

  • Real time sensitivity adjustment

  • Adopts quality sensors that can detect slightly leaked halogen gases

  • 355 mm flexible stainless steel probe

Detects:

  • Halogenated refrigerants(with Chlorine and Fluorine included)including, but not limited to:

    • CFCs R12, R11, R500, R503, etc

    • HCFCs R22, R123, R124, R502, etc

    • HFCs R34a, R404a, R125, etc

  • Ethylene oxide gas leaks in hospital sterilising equipment (it will detect the halogenated carrier gas)

  • SF-6 in high voltage circuit breakers
  • Most gases that contain Chlorine, Fluorine, and Bromine (halogen gases)

  • Cleaning agents used in dry cleaning applications such as chloroethylene

  • Halogen gases in fire-extinguishing system.

Specifications:

  • Max sensitivity to halogenated refrigerants:3 g/y

  • Working temperature:0~50 C

  • Working mode:Continuous and no limit

  • Reaction time: Instant

  • Resetting time:2 seconds

  • -up time:about 6 seconds

  • Probe length: 355 mm

#4.WIPCOOL Tube Cutter – 4-32mm

HC32

This WIPCOOL HC32, Tube Cutter is a quality, high precision, smooth action telescopic tube cutter with the tightest possible constant turning radius. This tube cutter is for cutting copper, brass, aluminium, stainless steel and thin-walled steel tubing.

Features:

  • Compact construction, with sturdy aluminium casting

  • Spare cutting wheel in handle

  • Black plated, enclosed threaded spindle to protect against dirt and jamming

  • Foldaway reamer and integral spare cutter wheel in handle knob

  • Enclosed feed action with sturdy aluminium body guarantees sharp and accurate cuts time after time

  • 432 mm

Reviews

There are no reviews yet.

Be the first to review “HVACDIRECT Refrigeration & HVAC Split System Install Kit (Pump, Leak Detector, Tube Cutter & Manifold Set)”

Your email address will not be published. Required fields are marked *